How To Guide:
Source: LAUNCH TECH CO LTD
LAUNCH Ford F-150 2019 TAD Calibration
Just a Heads-Up: This guide is here to help you out, but it’s for general info only. We try to keep everything accurate and reliable, but we can’t promise it’s perfect. So, if you decide to follow this guide, you’re doing it at your own risk. We’re not responsible for any loss or damage that might happen, including indirect or consequential loss, or any loss of data or profits from using this guide. Sometimes, we might link to other websites. We don’t control those sites, so we can’t vouch for their content. Just because we link to them doesn’t mean we endorse them. We do our best to keep this guide running smoothly, but we can’t be held responsible if it’s temporarily unavailable due to technical issues beyond our control.
Ford F-150 2019 TAD Calibration
Supported Model/Model Year:
Ford 2019 F-150
Features:
When removing or replacing the front/rear camera, IPM-B module or guided by TSB (Technical Service Briefing) maintenance manual, this function is needed to perform. And this function needs to cooperate with Target LAC04-07.
Requirements:
Communication is normal, battery voltage is between 12V and 15V, and all doors, trunk, and hood are closed;
If the IPMB (Image Processing Module B) is replaced, please execute "IPMB Programmable Module Installation" under the module programming menu before continuing this procedure;
If the front or rear camera is replaced, please execute "LIN New Module Initialization-IPMB (Image Processing Module B) Maintenance Function" before continuing this procedure;
Execute IPMB (Image Processing Module B) read the fault code, and execute clear the fault code before continuing this procedure.
Software version:
Select Ford V48.50 or above.
Product requirements:
X431 PRO3/3S/3S+/5 series products, PAD series products, X-431 ADAS target LAC04-07.
Steps:
1. Select [Auto Search]
2. Confirm current vehicle information
3. Select [Special Features] (or select ADAS (Advanced Driver Assistance System) Calibration)
4. Select [Electrical]
5. Select [Service function]
6. Select [TAD Calibration]
7. Prompt to perform the function, prerequisites for the vehicle
8. Prompt the surrounding environment to ensure enough space and precautions for the vehicle
9. Place the target correctly according to the prompts (Figure below). Take F-150 as an example: Mark 1 is 2400mm.
10. Prompt the time required for calibration
11. Prompt to start calibration
12. Prompt that the calibration is successful
13. Exit the function, and return to the menu to clear the fault code.