SmartSafe ADAS PEUGEOT BOXER3 Euro 5 | Euro 6 Front Camera Calibration
Just a Heads-Up: This guide is here to help you out, but it’s for general info only. We try to keep everything accurate and reliable, but we can’t promise it’s perfect. So, if you decide to follow this guide, you’re doing it at your own risk. We’re not responsible for any loss or damage that might happen, including indirect or consequential loss, or any loss of data or profits from using this guide. Sometimes, we might link to other websites. We don’t control those sites, so we can’t vouch for their content. Just because we link to them doesn’t mean we endorse them. We do our best to keep this guide running smoothly, but we can’t be held responsible if it’s temporarily unavailable due to technical issues beyond our control.
Function Description:
The front camera needs to be calibrated in the following cases:
(1) The vehicle has the following failure records (no or wrong basic settings/adaptation)
Camera not calibrated or incorrectly calibrated.
(2) Vehicle parts are overhauled and replaced as follows:
Replace the controller
Removed and reinstalled or replaced windshield
Updated one of the vehicle height sensors for the height control system
Measured models:
BOXER3_Euro 5 | Euro 6
Operation guide:
1. Automatically identify and enter through ADAS calibration entrance VIN.
2. Choose "ADAS Calibration".
3. Automatically recognize BOXER3_Euro 5 | Euro 6 models.
4. After selecting "ADAS System Select", click "Lane Wandering Alert" to enter the system.
5. Select the path Special Function->ADAS Calibration, and click to enter.
6. Select the "ADAS MOBILE" target, read the prompts, get ready, and click "OK".
7. Follow the prompts, and click "Next Step" after completing the operation.
8. Follow the prompts, and click "Next Step" after completing the operation.
9. Follow the prompts, and click "Next Step" after completing the operation.
10. Follow the prompts, and click "Next Step" after completing the operation.
11. Follow the prompts, and click "Next Step" after completing the operation.
12. Follow the prompts, and click "Next Step" after completing the operation.
13. Follow the prompts, and click "Next Step" after completing the operation.
14. Follow the operation, after completing the prompts, click the "NEXT" button to execute the calibration function, turn off the ignition after the prompts appear, and then click "OK".
15. According to the prompt, after turning on the ignition, click "OK".
16. When the calibration is successful, click "OK".