Launch EM101N EV Oscilloscope & Multimeter
EM101N EV OSCILLOSCOPE & MULTIMETER integrates the functions of a multimeter and a dual-channel oscilloscope, which can be used for two purposes.
The detection and maintenance of the power system is important for new energy vehicles. By viewing the waveform diagram, the maintenance progress can be improved. This product integrates the functions of a multimeter and a dual-channel oscilloscope, which can be used for two purposes. The brand-new diagnostic APP is user-friendly, easy to use and convenient, supports the function of saving and opening waveforms locally.
- Combined with the characteristics of dual-channel oscilloscope and multimeter.
- The anti-fall rubber sleeve increases the protection of the product, and the unique fuse plug-in design is convenient for replacement.
- With X-431 diagnostic tool, it can be connected wirelessly or in wired mode, which can be freely selected. With X-431 diagnostic tool, the new UI design supports three display modes, which can be freely switched. Needle sets, multimeter pens, alligator clips, oscilloscope channel test leads, etc. are all available.
DC VOLTAGE
Automatic range, test range: ±600V
AC VOLTAGE
Automatic range, test range: ±600V
DC CURRENT
Automatic range, test range: ±10A
(It is necessary to connect an external sensor for large range current.)AC CURRENT
Automatic range, test range: ±10A. Average value measurement (It is necessary to connect an external sensor for large range current.)
RESISTANCE
Automatic range, test range: 0~6MΩ
ON AND OFF
Tweet when less than 30Ω
DIODE
0.5V-2.0V
BATTERY CAPACITY
3100mAh
BANDWIDTH
10MHz
CHANNEL
Two analog channels
REAL-TIME SAMPLING RATE (MAX)
50MHz/s
TIME BASE RANGE
1us/div~10s/div, step by 1~2~5 times
SAMPLING MODE
Normal sampling, peak detection, average
BUFFER MEMORY
1M
INPUT COUPLING
DC, AC, grounded
INPUT RESISTANCE
1MΩ±2%, Parallel with 15pF±5pF
VERTICAL SENSITIVITY
2mV/div~5V/div
VERTICAL RESOLUTION
8bits
MAXIMUM INPUT VOLTAGE
40V peak value (DC + AC peak value)
PROBE ATTENUATION FACTOR
1X, 10X, 100X (probe support required)
TRIGGER TYPE
Edge trigger, pulse width trigger
TRIGGER MODE
Auto, normal, single
AUTOMATIC MEASUREMENT
Peak-to-peak value, average value, maximum value, minimum value, top value, bottom value, frequency, period